Browse all practice questions for the Sheet Metal Journeyman Practice Test. Search by topic, open any question and review its full explanation, then test yourself in the practice quiz.

Sheet Metal Journeyman Practice Test course image
More practice questions

These questions are part of the practice quiz. Start practicing

  • A pre-fab double wall vertical vent for a gas furnace is commonly known as which vent type?
  • What is the maximum gas pressure allowed inside a building?
  • A wall mounted canopy hood used with a heavy duty cooking appliance shall have a minimum CFM per linear foot of hood of
  • Why are gaskets and sealants used on duct joints?
  • What minimum pitch per foot is required for the horizontal run of a vent connector?
  • Which component is primarily monitored by a flame safeguard on a boiler?
  • In area-based duct sizing, what is determined from cross-sectional area?
  • Why is material grain direction often considered in metal forming?
  • Any variable air volume system duct upstream of the VAV boxes shall meet seal class ______.
  • What is a relief near the corner used for in sheet metal patterns?
  • Which statement best identifies a good quality edge after punching or shearing?
  • What is a pilot hole and why is it used before rivet holes?
  • Who must approve the location of the gas delivery point in gas installations?
  • What is the primary purpose of wearing eye protection and face shields when cutting sheet metal?
  • When hanging a 36-inch round duct at 12-foot intervals, what is the minimum strap size?
  • What is galvanizing?
  • Type I hood seams are made with a continuous exterior liquid-tight joint by which method?
  • Which statement correctly reflects permit extensions?
  • Which standard do Type HT requirements for factory built chimneys in dwellings with solid fuel-burning appliances fall under?
  • A duct is permitted to penetrate three floors or less without a fire damper at each floor as long as the duct does not exceed _____ inches nominal diameter.
  • What test is commonly used to verify duct system airtightness?
  • Flat oval duct construction shall be capable of withstanding a pressure ______% greater than that of the assigned pressure class without structural failure or permanent deformation.
  • When using aluminum duct avoid which seam type?
  • What is a take-off elbow used for in duct routes?
  • If a 14 square foot intake ventilator is to be constructed, which sheet metal gauge is specified?
  • Aluminum has to be approximately what percent thicker than steel?
  • For rapid assembly with limited access or when disassembly is not required, which rivet type is preferred?
  • How can you verify that a bend angle matches the drawing after forming?
  • Which statement about leakage is true?
  • When would you choose to use a pop rivet instead of a solid rivet?
  • What device is installed to prevent a back draft occurring in an appliance?
  • How would you lay out a circle of holes on a panel to ensure exact spacing?
  • Why would you use a tighter radius on thin sheet metal bends?
  • Factory built chimneys installed in dwelling units with solid fuel-burning appliances shall comply with Type HT requirements of which standard?
  • For a strap hanger installation at 2.2 m spacing for a 1000 x 1000 mm duct, the hanger size should be which of the following?
  • What type of cut is produced by a nibbler that is different from a shear cut?
  • The duct described for a 40x20 oval duct with longitudinal seam uses which gauge?
  • Testing of a gas line with air, carbon dioxide or which gas?
  • What is hemming?
  • If kitchen exhaust interferes with appliance operation, which of the following must be provided?
  • What is the minimum clearance to combustible construction for exhaust serving a Type 1 hood?
  • What can deviations from project drawings cause in ductwork?
  • Which pipe material cannot be used on the exterior of a building or underground?
  • A permit to accomplish work may be extended a MAXIMUM of how many times?
  • A chimney for a low-heat appliance must withstand a continuous flue gas temperature not exceeding how many degrees Fahrenheit?
  • What is the area formula for a rectangle?
  • The volume of a room compared to the volume of a furnace to be installed is based on what maximum ceiling height?
  • Boilers require a shut-off valve in which part of the piping, ignoring exceptions?
  • What is a slip joint and what is it used for?
  • Why is material grain direction often considered in metal forming?
  • The termination point for a duct intended to exhaust flammable vapors shall be located a minimum of how many feet from any property line?
  • What is the function of a flange in sheet metal parts?
  • Which instrument is commonly used to measure duct pressure during an airtightness test?
  • What is one major advantage of using a nibbler over a shear cut when making curved contours?
  • A listed smoke damper designed to resist the passage of smoke shall be provided at each point a duct or air transfer opening penetrates which barrier?
  • What is the maximum distance that 1 1/4 inch copper tubing should be supported?
  • What is the primary purpose of a flange in sheet metal parts?
  • What is the overall objective of pattern development in sheet metal work?
  • Name two common rivet types used in sheet metal work and a basic use for each.
  • Which statement best describes circular take-off and rectangular take-off in ductwork?
  • A chimney for residential type or low-heat appliances shall exceed at least how many feet above the highest point where it passes through a roof?
  • What is the minimum size screw for a duct riser supported from a wall?
  • A pre-fab double wall vertical vent for a gas furnace is called which vent type?
  • What is the primary purpose of a slip joint in ductwork?
  • What is pattern development in sheet metal work?
  • What is beading?
  • At what temperature does duct work need to be insulated?
  • A chimney for a medium-heat appliance shall extend at least how many feet higher than any portion of any building within how many feet?
  • Given you are running a gas line and need to bore a hole in a joist. What is the clearance from the top to the bottom of the joist?
  • In gas piping, which metallic piping should not be used?
  • A furnace rated at 24,000 BTUH requires how many square inches of free air?
  • Longitudinal standing seams should be fastened every how many inches?
  • Why is it important to follow project drawings precisely?
  • Outdoor air openings may be located less than 10 feet horizontally from a street, alley, parking lot or loading dock, provided they are at least how many feet above such locations?
  • The minimum required volume for indoor combustion air is how many ft³/1000 BTU/hr?
  • Which pipe material cannot be used on the exterior of a building or underground?
  • Smoke detectors shall be located downstream of an air filter and ahead of any branch connectors in the return air stream with flow greater than how many cfm?
  • Which statement is true about a circular take-off in ductwork?
  • If gas piping is found defective, what action should be taken?
  • The return air duct to a blower type warm air furnace requires how many square inches of free air per 1,000 BTUH of rated capacity?
  • A furnace rated at 60,000 BTUH requires how many square inches of free air?
  • A liquid that condenses from a gas by a reduction in temperature is called
  • In pattern development, what is the centerline used for?
  • Which tool is commonly used to check whether a pattern piece is square?
  • In bending, what does the neutral axis represent?
  • Refrigerant safety is determined by toxicity and which property?
  • Which statement best describes the purpose of pattern development in sheet metal work?
  • What is the purpose of a relief cut near a bend line?
  • Rungs on a ladder SHALL NOT BE more than how many inches apart?
  • What is the BTU rating of a direct vent gas fireplace?
  • What is meant by the neutral axis in bending?
  • A furnace rated at 12,000 BTUH requires how many square inches of free air?
  • A health club shower room measuring 10 feet by 10 feet with four shower heads requires an intermittent exhaust capacity of how many CFM?
  • Supply and return air ducts in non-hazardous locations shall be supported at intervals of no greater than ______.
  • Using 22 ga. Paint grip, duct horizontally mounted to a wall, the allowable load per fastener is how many pounds?
  • Gypsum ducts are limited to a maximum temperature of which value?
  • How does K-factor influence bend allowances in layout?
  • For a 40x20 oval duct with a longitudinal seam, what is the duct gage?
  • Bend allowance is used to determine what parameter in sheet metal layout?
  • Ducts and plenums serving a Type II hood shall be constructed of ______ materials.
  • Which practice best minimizes waste by arranging parts efficiently on the sheet?
  • What is the minimum distance a floor furnace register can be from a wall?
  • A typical slot diffuser connection to the maximum flex length is how many feet?
  • What finishes protect sheet metal in humid environments?
  • What is bend allowance?
  • How do you check a bend angle for accuracy?
  • What is the formula for circumference of a circle?
  • In a shower room scenario, the intermittent exhaust capacity should be what value?
  • When an isolation transformer is provided, which safety devices prevent a boiler from operating once the ungrounded side becomes interrupted?
  • Which gauge is appropriate for a 26 inch round duct with positive pressure and a long seam?
  • Which statement correctly defines pattern development?
  • An intake ventilator measuring 14 square feet should be made of ______ ga. material.
  • What is a lock seam?
  • A listed gas water heater with a draft hood and a single wall metal vent connector needs to have how much clearance to combustible material?
  • A fuel fired furnace, measuring 22 cubic feet, must be placed in a room greater than how many cubic feet if it is not approved for closet installation?
  • Which element may be found on a sheet metal pattern drawing to convey additional information?
  • What is the role of punches and dies in sheet metal fabrication?
  • Intake openings in occupancies other than residential shall have a maximum screen opening size of how many inches?
  • Which of the following is a correct pairing of common seam types in ductwork?
  • When burrs are not removed after cutting, what hazards or issues can occur?
  • The flame spread distance for wires and cables in a plenum is 5 feet; which of the following is true?
  • The relief opening of a draft hood must be kept not less than how many inches from any surface other than the appliance it serves?
  • Which of the following statements about finishes is true for humid environments?
  • 26 inch round duct, positive pressure, un-reinforced long seam 4 inches W.G. can be made of which gauge?
  • What is the purpose of deburring after cutting?
  • A furnace rated at 7,500 BTUH requires how many square inches of free air?
  • Each spray booth and spray room shall have an independent exhaust duct system discharging to the
  • A joint that allows disassembly and alignment during installation most commonly uses which feature?
  • How would you minimize material waste when cutting multiple parts from a sheet?
  • A duct that penetrates up to three floors without a fire damper must have a maximum nominal diameter of how many inches?
  • What is the difference between a rivet and a bolt in sheet metal joints?
  • In hood duct systems, which material should be used?
  • Air exhausted from spraying operations shall be permitted to be recirculated as makeup air for unmanned spray operations provided that the vapor concentration is less than ______% of the lower flammable limit
  • Which gas, in addition to air and carbon dioxide, is used for testing gas lines?
  • Maximum flame spread distance for combustible electrical wires and cables and optical fiber cables exposed within a plenum is how many feet?
  • A type B or type L vent shall terminate at least ______ feet in vertical height above the highest connected appliance draft hood or flue collar
  • In ductwork assembly, what does a sliding fit in a slip joint primarily facilitate?
  • What is the neutral axis concept used for in bending?
  • Why is edge conditioning important before forming a bend?
  • For intakes in non-residential occupancies, the maximum screen opening size is which of the following?
  • The purpose of a flame safeguard on a boiler is to:
  • Makeup air recirculation for unmanned spray operations is permitted when vapor concentration is less than what percent of LFL?
  • Air transferred from occupied spaces may serve as makeup air for required exhaust systems in kitchens.
  • Which of the following is commonly shown as a dimension on a sheet metal pattern drawing?
  • Which option is not a finish used to protect sheet metal in humid environments?
  • Refrigerant is rated for safety by toxicity and:
  • Name three hand tools commonly used to cut sheet metal.
  • Which seam type should be avoided when using aluminum duct?
  • Given a machinery room ventilation system that terminates on the roof and an outside grille serving an air conditioning system in the penthouse, what is the minimum clearance between the discharge outlet and the intake for the air conditioning system?
  • Non-metallic ducts shall have a flame spread index of 25 or less and a smoke-developed index of 50 or less.
  • A Type L vent requires how many inches of clearance to combustibles?
  • Which statement best describes the difference between a punched hole and a drilled hole?
  • What is a burr and why must it be removed?
  • What minimum passage-way width is required around a boiler?
  • What process involves folding the edge to produce a smooth edge and add strength?
  • How does temperature affect duct joints?
  • At least how many feet of clearance shall be available between the access opening and the edge of the roof?
  • Which dimension is commonly seen on a sheet metal pattern drawing?
  • Where must the exhaust from a spray booth be discharged?
  • Disregarding exceptions, all boilers need a shut-off valve in the
  • The process by which a gas converts to a liquid when the temperature decreases is called?
  • Gypsum ducts are for return air only and limited to what maximum temperature in °F?
  • The maximum flame spread distance applies to which components when exposed within a plenum?
  • What is the purpose of a gap or seal at a seam?
  • What are the maximum flame spread and smoke-developed indices allowed for non-metallic ducts?
  • When selecting a bend radius for thin sheet metal, what must be verified to prevent cracking?
  • A duct system having all transverse joints and longitudinal seams sealed is a:
  • What is the primary advantage of lock seams in ductwork?
  • The location of the point of delivery shall be acceptable to the
  • The ceiling height used to determine the room-to-furnace volume ratio is what maximum?
  • How is duct sizing determined in the area method?
  • Which duct shape generally has fewer joints per length and thus less leakage?
Subscribe

Get the latest from Passetra

You can unsubscribe at any time. Read our privacy policy